Air-handling units
Coordinate coil connections with access doors and maintenance zones.
Airside equipment / water-side connections
Plan AHU and terminal water-side branches with defined flow, controls, balancing interfaces and maintenance access.
Application guide · design inputs
Application analysis
Build the branch schedule from each AHU, coil or terminal connection drawing. Record water-side duty, flow, pressure differential and dimensions. Allocate responsibility for isolation, control valves, balancing devices and measuring points.
Coordinate the branch with equipment access doors, insulation and maintenance space. Define drainage, venting, supports and movement allowances. Record installation, flushing, testing and commissioning responsibilities alongside the equipment schedule.
Coordinate coil connections with access doors and maintenance zones.
Prepare a consistent but duty-specific branch schedule.
Resolve the new equipment interface against existing distribution.
Concept arrangement / 11
Select a review point to inspect the source, controls and distribution of a representative utility module.
Water-side supply — Confirm the distribution conditions serving the terminal.
Engineering review
| Design input | What it changes | Evidence to request |
|---|---|---|
| Terminal data | Align the branch with coil duty and connection limits. | Equipment schedule, flow and connection drawings. |
| Control interface | Allocate balancing and control responsibilities. | Control-valve data and commissioning requirements. |
| Space & insulation | Maintain equipment access around the completed pipework. | Insulation envelope and maintenance clearances. |
| Movement & supports | Avoid imposing unreviewed loads on equipment nozzles. | Support arrangement and mechanical movement assessment. |
Part-number starting points
Review catalogue dimensions, materials and connection types alongside the service schedule. Add selected part numbers to your enquiry.
Specify the size, pipe outside diameter, material, seal, joining system and tool. Include the intended duty and required product acceptance documents with the enquiry.
Prepare the next conversation
Questions worth resolving
List flow, pressure differential, connection dimensions, isolation/control/balancing requirements and access clearances.
Group terminals by their documented duty and connection requirements, then record the branch arrangement for each type.
HVAC focuses on AHU and terminal interfaces. Cooling & Heating covers thermal plant and the wider hydronic distribution arrangement.
Connected applications